Steam bath milk
Electrodes or heating elements?
A steam generator can produce steam using heating elements (Keulertz, EOS) or electrodes (VAPAC).
With heating elements, 1.3 kg of steam per hour is produced per 1 kWh of electricity; when using electrodes, this is 1.1 kg of steam per hour.
Heating elements are therefore more efficient but can only be used in lime-free water, whereas a steam generator with electrodes actually needs lime to function.
For steam generators with heating elements, the length of the elements is also important. The longer the elements, the larger the surface area that is in contact with the water.
Required power of the steam generator
Because the chosen system (electrodes or heating elements) determines the efficiency, we provide the required steam production in relation to the volume of the steam cabin and the required power in the table below.
| Steam cabin volume |
Steam production per hour |
Power for heating elements |
Power for electrodes |
| 2.5 - 4.0 m3 | 6 kg/hour | 4.5 kW | 5.5 kW |
| 3.0 - 5.0 m3 | 8 kg/hour | 6.0 kW | 7.0 kW |
| 5.5 - 10.0 m3 | 12 kg/hour | 9.0 kW | 11.0 kW |
| 9.5 - 12.0 m3 | 16 kg/hour | 12.0 kW | 14.5 kW |
| 11.5 - 15.0 m3 | 20 kg/hour | 15.0 kW | 18.0 kW |
| 14.5 - 18.0 m3 | 24 kg/hour | 18.0 kW | 22.0 kW |
Lime
Lime is THE enemy of every steam generator. Yet, a steam generator with electrodes actually needs lime to function. This is precisely why a steam tank (with electrodes) can always be easily replaced. For professional use, this should be done approximately once a year.
A steam generator with heating elements should not have any lime at all. Otherwise, the evaporation of the water would cause lime deposits to build up on the elements. This build-up prevents the heating elements from effectively transferring their heat to the water, which can cause them to burn out. We therefore recommend ALWAYS installing a water softener before the steam generator and reducing the lime to 0. The water is then no longer suitable as drinking water.
Steam bath fragrance
A steam cabin always needs a fragrance, otherwise it will start to smell. The most commonly used fragrance is Eucalyptus-Mint steam bath milk. Steam bath milk is dosed directly into the steam pipe, just before it enters the steam cabin. If the injection point is too close to the steam generator, the fragrance can enter the steam tank, causing it to malfunction.
Depending on the dosing system, the steam bath milk sometimes needs to be diluted with water. We always recommend using a dosing system where you do not need to dilute. You dilute using water, and over time, separation will occur, meaning the fragrance intensity is not always constant; furthermore, different users will dilute in different ways, which also leads to variations.
A properly calibrated dosing pump can function very well with concentrated steam bath milk. This results in a more consistent fragrance experience.
See: https://alternatief.com/collections/doseersysteem-stoomkabines